4 Stages Of Bearing Failure
Stage 1
Vibration analysis is used to detect the earliest signs of bearing faliure. Ultasonic frequency bands around 250 KHz to 350 KHz start to give signals. Roughly, there is approximately 10-20% remaing life on the bearing.
Stage 2
Signal appears at the first harmonic frequency of the bearing at (500 to 2,000 Hz). Faliure of the bearing begins to "ring" translation to 5-10% remaing life.
Stage 3
Fundemental frequency is apparent with bearing faliure harmonics. Inner and outter race defects are now noticable on vibration analysis of the noise signal.
Stage 4
High vibration indicates bearing faliure. The harmonics and fundamental start to actually degrade, while random noice greatly rises, and bearing temperature rapidly increases. These signs indicate about one hour to one percent of remaining life.